[GTMP] Temperature Gradient

"GTMP": { "ITEMS": { "__DESC__": "Items", "__TYPE__": [ { "ID": { "__DESC__": "ID", "__TYPE__": "Integer" }, "LCNAME": { "__DESC__": "Load Case Name", "__TYPE__": "String" }, "GROUP_NAME": { "__DESC__": "Name of Load Group", "__TYPE__": "String" }, "TYPE": { "__DESC__": "Temperature Type (Beam / Plate)", "__TYPE__": "Integer" }, "TZ": { "__DESC__": "Tz", "__TYPE__": "Real" }, "USE_HZ": { "__DESC__": "Set Use Property Hz", "__TYPE__": "Bool" }, "HZ": { "__DESC__": "Hz", "__TYPE__": "Real" }, "TY": { "__DESC__": "Ty (Beam/USE_PROP_HZ=false)", "__TYPE__": "Real" }, "USE_HY": { "__DESC__": "Set Use Property Hy", "__TYPE__": "Bool" }, "HY": { "__DESC__": "Hy (Beam/USE_PROP_HY=false)", "__TYPE__": "Real" } } ] } }

 

  • Introduce Input Data Symbols

API - Value Type

Input Data

API - Value Type

Input Data

Integer

🔴

Essential

String

Unnecessary

Boolean

🔺

Optional

Real

 

 

 

  • The required Input Data for defining Temperature Gradient

NO.

Name

API - Key

API - Value Type

Default

Temp.

Gradient

NO.

Name

API - Key

API - Value Type

Default

Temp.

Gradient

1

Node No.

"KEY"

 

🔴

2

 

"ITEMS"

 

 

🔴

3

Serial Number

  • If Add or Replace

"ID"

0

🔺

4

Load Case Name

"LCNAME"

 

🔴

5

Load Group Name

"GROUP_NAME"

 

🔺

6

Element Type

  • Beam : 1

  • Plate : 2

"TYPE"

 

🔴

 

Gradient

7

T2z - T1z

"TZ"

 

🔴

8

Use Section Hz

"USE_HZ"

FALSE

🔺

9

Hz value

"HZ"

 

🔴

 

Beam Type Only

10

T2y-T1y

"TY"

 

🔴

11

Use Section Hy

"USE_HY"

FALSE

🔺

12

Hy value

"HY"

 

🔴

 

  • The JSON format example for inputting Temperature Gradient

"GTMP": { "1001": { "ITEMS": [ { "ID": 1, "LCNAME": "LC3", "GROUP_NAME": "L1", "TYPE": 1, "TZ": 1.11, "USE_HZ": true, "HZ": 0.0, "TY": 2.22, "USE_HY": true, "HY": 0.0 } ] } }
"GTMP": { "1005": { "ITEMS": [ { "ID": 1, "LCNAME": "LC4", "GROUP_NAME": "", "TYPE": 2, "TZ": 1.111, "USE_HZ": true, "HZ": 0.0 } ] } }